Tripping RCDs and breakers in Middlesbrough
A breaker or RCD that keeps tripping is your consumer unit telling you something is wrong. It can be maddening when it happens halfway through cooking tea or knocks the heating out overnight, but the switch is doing its job. Our emergency electricians in Middlesbrough find out what is setting it off and repair the fault so the power stays on.
Which switch has gone?
It helps to know what you are looking at. An MCB (miniature circuit breaker) guards a single circuit against overload and short circuits. An RCD watches for current leaking to earth, the kind of fault that could give someone a shock, and usually cuts several circuits at once. An RCBO combines both jobs for one circuit, and older boards may still have rewireable fuses. Telling us which one has dropped when you ring helps us narrow things down before we arrive.
Common reasons for repeated tripping
- A kettle, washing machine, oven element or immersion heater leaking current
- Rain getting into garden sockets, outside lights or junction boxes (water and flood damage)
- A cable nicked by a nail, screw or drill bit
- Lots of appliances on one RCD adding up small leakages
- An ageing RCD that has grown oversensitive
- Neutral and earth conductors touching somewhere in the wiring
A safe check you can try yourself
Unplug or switch off everything on the affected circuits, then reset the RCD or breaker once. Plug items back in one by one. If it trips as a particular appliance comes on, leave that appliance unplugged until it has been checked. If it trips with nothing plugged in, or will not reset at all, the fault is in the wiring and needs an electrician. Never tape a switch up or hold it in the on position. If you notice a burning smell as well, read our burning smells page, and call 999 if there is any smoke.
Reaching you across Teesside
Tripping calls from the town centre, Albert Park and Gresham are usually reached within 30 minutes. Linthorpe, Acklam, Nunthorpe, Eston and Coulby Newham fall within about an hour, with Stokesley, Great Ayton, Saltburn, Guisborough and Ingleby Barwick usually within 90 minutes. Check the response times for your area; we will also give you a straight answer on the phone. If tripping is only one symptom among several, our emergency fault finding service takes a wider look.
How we put it right
We test the insulation on each circuit and check that every RCD trips when it should. Then we repair the damaged cable or fitting, advise you on any faulty appliance or replace a failing device. Before we leave, the protection is retested, the job certified to BS 7671 and our repair guaranteed.