Tripping RCDs, breakers and fuses in Oxford
Few electrical problems are as frustrating as a consumer unit that won't stay on. In Oxford homes, flats and shops, it's one of the most common reasons we get a call late at night. The good news is that the tripping itself is the protection working: an RCD, MCB or fuse has spotted something wrong and cut the supply. Our job is to find out what.
Which switch has gone?
Knowing which device tripped narrows things down. An MCB guards a single circuit against overload and short circuits. An RCD watches for current leaking to earth and cuts out within a fraction of a second, often taking a whole bank of circuits with it. An RCBO does both jobs for one circuit. Older boards may still have rewireable fuses, where a thin wire melts. Tell us what you can see when you call.
Narrowing it down yourself, safely
Turn off and unplug everything on the affected circuit, then reset the switch once. Plug things back in one at a time. If it trips when a particular appliance goes on, leave that appliance unplugged until it's checked. If it trips with nothing plugged in, or won't reset at all, the fault is in the fixed wiring, so leave it off and call us. Never tape a switch up or wedge it in the on position.
Usual causes we find
- Kettles, washing machines, ovens and immersion heaters leaking current
- Damp in outdoor sockets and garden lighting, particularly after rain (see water damage to electrics in Oxford)
- A cable nicked by a nail or screw
- Lots of appliances sharing one RCD, their small leakages adding up
- A tired RCD that trips too easily
- Neutral-to-earth faults in the wiring
How soon we can be there
Tripping in central Oxford, near the colleges or around Grandpont, usually gets an electrician within 30 minutes. For Headington, Cowley, Summertown and Botley, plus Jericho, Iffley and Blackbird Leys, it's usually within 60 minutes. Kidlington, Abingdon, Wheatley and Eynsham, and villages out to Garsington and Chalgrove, are usually within 90 minutes. The ring road can slow us at peak times, so we'll be straight with you about timing. Check our Oxford response zones.
Fixing it for good
On site, insulation and RCD tests show exactly where the leakage or overload is. If it's an appliance, we tell you which one and leave it unplugged. If it's the fixed wiring, we repair the damaged cable or fitting, then test the protective device so it trips when it should and stays on when it shouldn't. We only suggest a new consumer unit if it's genuinely needed, and where one circuit has to stay off for now, the rest of the property is switched back on safely. If the cause is less clear-cut, our emergency fault finding in Oxford takes it further.