‹ Emergency electrician Oxford

Tripping
RCDs & fuses
in Oxford

If a switch on your consumer unit keeps dropping, it's warning you about a fault. We track down what's triggering it and fix it so the power stays on.

  • RCDs, MCBs, RCBOs and old fuses covered
  • Appliance or wiring fault identified
  • RCDs tested on site after the repair
  • Fixed at the cause, not just reset
Tripping fuses & RCDs in Oxford photo

What we deal with in Oxford

Tripping is a symptom rather than the fault itself. These are the patterns we see most in Oxford homes and businesses.

  • RCD drops out and refuses to reset
  • Breaker flips when the kettle or oven is on
  • Tripping every time it rains heavily
  • Power off by morning with no clear reason
  • Rewireable fuse wire that keeps melting
  • Trouble ever since a new dishwasher went in
  • Garden lights or outside socket knocking power off
  • Several circuits lost from one RCD trip

Tripping RCDs, breakers and fuses in Oxford

Few electrical problems are as frustrating as a consumer unit that won't stay on. In Oxford homes, flats and shops, it's one of the most common reasons we get a call late at night. The good news is that the tripping itself is the protection working: an RCD, MCB or fuse has spotted something wrong and cut the supply. Our job is to find out what.

Which switch has gone?

Knowing which device tripped narrows things down. An MCB guards a single circuit against overload and short circuits. An RCD watches for current leaking to earth and cuts out within a fraction of a second, often taking a whole bank of circuits with it. An RCBO does both jobs for one circuit. Older boards may still have rewireable fuses, where a thin wire melts. Tell us what you can see when you call.

Narrowing it down yourself, safely

Turn off and unplug everything on the affected circuit, then reset the switch once. Plug things back in one at a time. If it trips when a particular appliance goes on, leave that appliance unplugged until it's checked. If it trips with nothing plugged in, or won't reset at all, the fault is in the fixed wiring, so leave it off and call us. Never tape a switch up or wedge it in the on position.

Usual causes we find

  • Kettles, washing machines, ovens and immersion heaters leaking current
  • Damp in outdoor sockets and garden lighting, particularly after rain (see water damage to electrics in Oxford)
  • A cable nicked by a nail or screw
  • Lots of appliances sharing one RCD, their small leakages adding up
  • A tired RCD that trips too easily
  • Neutral-to-earth faults in the wiring

How soon we can be there

Tripping in central Oxford, near the colleges or around Grandpont, usually gets an electrician within 30 minutes. For Headington, Cowley, Summertown and Botley, plus Jericho, Iffley and Blackbird Leys, it's usually within 60 minutes. Kidlington, Abingdon, Wheatley and Eynsham, and villages out to Garsington and Chalgrove, are usually within 90 minutes. The ring road can slow us at peak times, so we'll be straight with you about timing. Check our Oxford response zones.

Fixing it for good

On site, insulation and RCD tests show exactly where the leakage or overload is. If it's an appliance, we tell you which one and leave it unplugged. If it's the fixed wiring, we repair the damaged cable or fitting, then test the protective device so it trips when it should and stays on when it shouldn't. We only suggest a new consumer unit if it's genuinely needed, and where one circuit has to stay off for now, the rest of the property is switched back on safely. If the cause is less clear-cut, our emergency fault finding in Oxford takes it further.

While you wait

Stay safe until we reach you

Do these if you can do them safely. Your electrician will take it from there.

  1. 01Unplug everything on the circuit before one reset attempt
  2. 02Add appliances back one by one to spot the culprit
  3. 03Never tape a breaker up or hold it on
  4. 04Trips with nothing plugged in? Leave it off and call us

How we handle it

  1. Step 01

    When does it trip?

    Straight away, overnight, in the rain or with one appliance? The pattern tells us a lot.

  2. Step 02

    Circuits tested

    Insulation tests on each circuit show where current is escaping.

  3. Step 03

    Culprit confirmed

    We show you the faulty appliance, cable or fitting before agreeing the repair.

  4. Step 04

    Protection rechecked

    After the repair we test the RCD so it keeps protecting you and stays on.

Tripping fuses & RCDs in Oxford: FAQs

Why does my power go off in the middle of the night?

Often an appliance on a timer, such as a dishwasher, storage heater or outside light, or damp settling as the temperature drops. We test to find out which.

Why does everything trip after a heavy downpour?

Water is usually getting into an outdoor socket, garden light or exposed cable. We'll find where it's getting in and repair or replace the fitting.

Is it OK to keep flicking the breaker back up?

Try it once only. If it trips again straight away, leave it off and call us, because it's protecting you from a fault.

Could a single faulty kettle really black out the whole house?

It can, if several circuits sit behind one RCD. Any appliance leaking current on those circuits will take the lot out.

How long will I wait for an electrician to sort out tripping in Oxford?

The city centre is usually reached within half an hour. Allow about an hour for areas like Marston, Iffley and Cowley, and up to 90 minutes for Kidlington and the surrounding villages.

Will I need a new fuse board?

Rarely. Most tripping comes from an appliance or one faulty circuit, and we only recommend a replacement if it's really needed.

Breaker won't stay on?

Ring us day or night and an Oxford electrician will find what's tripping it.

Call Now: 01234 567 890