Tripping fuses and RCDs in Newcastle, traced to the source
If a switch on your consumer unit in Newcastle keeps tripping, it isn't being awkward. It has spotted something wrong and cut the supply to protect you, and our job is to find out what. We cover homes and businesses across Newcastle upon Tyne, Gateshead and North Tyneside, day and night, and treat a switch that won't reset as an emergency.
Which switch has gone?
It helps to know what you're looking at. An RCD watches for current escaping to earth, the kind of leak that could give someone a shock, and often guards several circuits at once. An MCB, or miniature circuit breaker, protects a single circuit from overload or a short. An RCBO combines both jobs for one circuit, and older boards may still use fuse wire that melts when overloaded. Tell us which one has dropped and we arrive with a head start.
Narrow it down yourself, safely
- Unplug everything on the affected circuits, or switch it off at the wall
- Lift the RCD or breaker, just the once
- Plug appliances back in one by one and note which brings it down
- If it drops with nothing plugged in, the fault is in the fixed wiring, so leave it off
Never tape a switch up, wedge it or hold it in position. If you see smoke or flames, or someone has had a shock, call 999. Should the tripping come with a smell of burning, turn off the main switch if it is safe to do so and read our burning smells and hot sockets advice.
What usually sets it off
Most of the time the cause turns out to be an appliance with a worn element or damaged lead, moisture in an outside socket or garden light, a cable nicked by a screw, or too many appliances adding their small leaks onto one RCD. Night-time tripping often points to something on a timer, such as a storage heater or a dishwasher. Tripping that follows rain usually means water has got into an outdoor fitting, while leaks indoors are covered on our water damage page.
Getting to you, and putting it right
Homes and businesses in the city centre and on the Quayside are usually reached within 30 minutes, whether that is off Grey Street, near the Haymarket or down in Ouseburn. Jesmond, Gosforth, Heaton and Fenham, and neighbouring Byker, Kenton, Walker, Elswick and Benwell, usually see us within 60 minutes. For Whickham, Gateshead, Wallsend and Ponteland, and further out to Newburn, Low Fell, Killingworth and the Team Valley, allow up to 90 minutes. Rush-hour crossings of the Tyne can vary, so expect an honest estimate on the phone and a live arrival text. The zones are laid out on our main Newcastle page.
Once we're there, we test insulation and the RCDs themselves, find the fault and fix it: a repaired cable, a replaced fitting, a failed RCD swapped, or clear advice on an appliance that needs to go. Then every circuit we touched is retested, you get a BS 7671 certificate, and the repair carries our guarantee.